one.two.2 Warning Labels Warning Labels Meaning Please carefully look at this manual right before use machine. The following labels really are a. Will not place the system on a sloped surface area. If not the readily available when the process device may possibly slide, causing private harm or maybe the gadget will work Using the cellular malfunction.

The DP-fifty Qualified is surely an ground breaking, high-effectiveness Ultrasound Process engineered that will help you get the insights you'll need. The Process’s impressive motor and significant-speed processing offer exceptional image high-quality and a whole info administration Remedy.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

The chapter provides the tactic to confirm principal function and general performance of products. This is certainly only utilized for reference, not preventive execution. Function checking and tests of this section shall be completed by Mindray service engineers plus the user jointly. Web page 66: Normal Exam

Function: About the again-stop of the main board, a Exclusive keep track of IC is applied to observe sign voltages  and clock battery electrical power that are presented to the main board by the primary unit box electric power source module.

Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.

5.2.3 Geometric positioning precision Longitudinal geometric positioning accuracy  Exam Phase: Do changes as the way in which in testing the most depth. File the gap by 20mm Just about every section over the longitudinal targets line utilizing the measurement caliper; Decide on the value with the best mistake (to 20mm), compute the accuracy utilizing the system under The measurement caliper must be positioned in the higher edge of the target, Take note:... Site 79 Transverse geometric positioning precision  Examination Stage: Include the scan area with the phantom with water or few gel, Carefully Call the probe With all the scan surface Change the depth, creating the transverse targets to generally be displayed in the picture. Alter the main target position to generally be posited beside the transverse targets (the common is not crystal clear) Adjust parameters like achieve, TGC, earning Each and every transverse targets to generally be clearly displayed. Webpage 80 5.5.two.four Blackout Area Check Phase: Address the scan surface of your phantom with h2o or pair gel, Carefully contact the probe With all the scan surface area Alter the depth at a decrease worth, and set the focus at the nearest place to the scan surface. Reduce the value of parameters like AP, Acquire until eventually the qualifications noise just could be observed. Web page eighty one: Computer software Update And Maintenance

Notice: Before uploading the log, be sure the ultrasound system is connected to network, in any other case, the technique may perhaps alert “could not connect with server” The server (smtp.

Right after changing the CPU module, vital file need to be produced once again based on the new MAC address and penned into HDD of your device. Or else, the configuration function with the solution will probably be shed. Soon after removing the CPU module, Clear away panhead screws with washers (twelve M3X6) mounted on the primary unit box, you can take off the board. Site 118 Determine eight-29 Disassemble the User interface Assembly (one) Keep the higher edge of user interface assembly, and open up up the user interface. Determine 8-thirty Disassemble the User interface Assembly (2) Following taking away 1 countersunk head self-tapping screw PT3X10 mounted over the user interface and take out the plug in the keyboard and the leading unit connecting cables, you could potentially eliminate the control panel assembly.

Any time you prevent the scanning and the image seize, you'll want to power off the program and disconnect the program from your AC electrical power provide, then pull out AC energy cables. Web page 109: Battery Connecting Board

This handbook may well referring to facts secured by copyright or patents and won't convey any license underneath the patent rights or copyright of Mindray, Dp50rb login or of others. Page nine: Assertion

probe. The impression abnormality could possibly be due to Substitute the probe, or maybe the swivel with the 4D probe or even the 4D push substitute the 4D travel board board.

Be aware: About the observe, the brightness adjustment will come before distinction. After readjusting the check’s contrast and brightness, modify all preset and peripheral settings.